Remote command:
For "RReq":
SEARch:TRIGger:MPHY:RREQ on page 1910
For "CReq"
SEARch:TRIGger:MPHY:CREQ on page 1910
Credit
Sets the specified credit to be searched for. The credit setup consists of the condition
and one or two credit patterns.
Credit represents the total number of credits available since boot time.
"Condition"
Defines the operator to set a specific credit, e.g. "Equal" or "Not
Equal" or a range.
"Data Min/Data"
Defines the bit pattern of the credit pattern.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor", on page 519.
"Data Max"
The second credit pattern is required to specify a range with condi-
tions "In range" and "Out of range".
Remote command:
SEARch:TRIGger:MPHY:CREDit:CONDition on page 1911
SEARch:TRIGger:MPHY:CREDit:MIN on page 1911
SEARch:TRIGger:MPHY:CREDit:MAX on page 1911
PACP Begin
Sets the specified PACP Begin to be searched for. The PACP Begin setup consists of
the condition and one or two PACP Begin patterns.
"Condition"
Defines the operator to set a specific PACP Begin, e.g. "Equal" or
"Not Equal" or a range.
"Data Min/Data"
Defines the bit pattern of the data value pattern.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor", on page 519.
"Data Max"
The second PACP Begin pattern is required to specify a range with
conditions "In range" and "Out of range".
Remote command:
SEARch:TRIGger:MPHY:PBEGin:CONDition on page 1912
SEARch:TRIGger:MPHY:PBEGin:MIN on page 1912
SEARch:TRIGger:MPHY:PBEGin:MAX on page 1912
PACP Function ID
Sets the specified PACP Function ID to be searched for. The PACP Function ID setup
consists of the condition and one or two PACP Function ID patterns.
"Condition"
Defines the operator to set a specific PACP Function ID, e.g. "Equal"
or "Not Equal" or a range.