Protocol analysis
R&S
®
RTP
864User Manual 1337.9952.02 ─ 12
Hysteresis
Sets a value for the hysteresis of the strobe/data signal.
Remote command:
BUS<m>:SWIRe:STRBe:HYSTeresis on page 2107
BUS<m>:SWIRe:DATA:HYSTeresis on page 2106
Show thresholds
If enabled, the threshold levels are displayed in the diagram.
Remote command:
BUS<m>:THReshold on page 1549
13.21.2.2 Advanced settings
Access: [Protocol] > "Advanced" tab.
Bit Position
Sets the bit position, the align position for the manual synchronization mode. This can
be useful when parity errors exist in the signal, and parity check is the main indicator
for the decoder to do packet alignment.
Remote command:
BUS<m>:SWIRe:BPOSition on page 2106
Min Gap
SpaceWire can have idle phases where strobe and data signals are not being sent.
These "gaps" are identified to resume decoding after this idle time.
"Min Gap" sets the minimum duration of a gap. Any inactivity greater than this time is
interpreted as a gap and lead to a resynchronization to the signal.
Remote command:
BUS<m>:SWIRe:MGAP on page 2107
Sync Settings
Sets the mode for the synchronization of the signal. In the auto mode, the decoder
automatically does the packet align. In the manual mode, you can set the align point
manually with the "Bit Position" setting.
Remote command:
BUS<m>:SWIRe:SYSLect on page 2108
SpaceWire (option R&S
RTP-K65)

Table of Contents