Remote control commands
R&S
®
RTP
2129User Manual 1337.9952.02 ─ 12
BUS<m>:CTLE:P2FReq <PoleTwoFreq>
Sets the pole 2 frequency for the transfer function of the CTLE algorithm.
Suffix:
<m>
.
1..4
Parameters:
<PoleTwoFreq> Range: 1 to 40E+9
Increment: 1
*RST: 0
Default unit: Hz
BUS<m>:CTLE:Z1FReq
<ZroOneFreq>
Sets the zero frequency for the transfer function of the CTLE algorithm.
Suffix:
<m>
.
1..4
Parameters:
<ZroOneFreq> Range: 1 to 40E+9
Increment: 1
*RST: 0
Default unit: Hz
BUS<m>:PCIE:DFE:AUTO <AutoChEstimate>
Enables the auto channel estimation.
Suffix:
<m>
.
1..4
Parameters:
<AutoChEstimate> ON | OFF
*RST: ON
BUS<m>:PCIE:DFE:COEFficient <DFEcoeff>
Sets the value of the coefficient for the DFE .
Suffix:
<m>
.
1..4
Parameters:
<DFEcoeff> Range: -1 to 1
Increment: 1E-3
*RST: 0
Default unit: V