15.3 Waveform Setup
Automatic Setup....................................................................................................299
Vertical Setup........................................................................................................299
Horizontal Setup....................................................................................................305
Acquisition Control................................................................................................ 306
Trigger...................................................................................................................309
15.3.1 Automatic Setup
AUToscale
Performs an autoset in scope mode.
Usage:
Event
15.3.2 Vertical Setup
The channel suffix <m> selects the channel for which the command is executed. The
number of channels depends on the instrument type. The R&S RTH1004 has 4 chan-
nels, the suffix values are 1 | 2 | 3 | 4. The R&S RTH1002 has 2 channels, the suffix
values are 1 | 2.
Make sure to set the attenuation factor on the instrument according to the probe being
used. Otherwise, the measurement results do not reflect the actual voltage level, and
you might misjudge the actual risk.
CHANnel<m>:STATe...................................................................................................... 299
CHANnel<m>:SCALe..................................................................................................... 300
CHANnel<m>:RANGe.................................................................................................... 300
CHANnel<m>:PROBe.................................................................................................... 300
PROBe<m>:SETup:ATTenuation:MANual.........................................................................301
PROBe<m>:SETup:ATTenuation:UNIT.............................................................................301
CHANnel<m>:POSition...................................................................................................302
CHANnel<m>:OFFSet.................................................................................................... 302
CHANnel<m>:COUPling.................................................................................................302
CHANnel<m>:BANDwidth...............................................................................................302
CHANnel<m>:DESKew.................................................................................................. 303
CHANnel<m>:THReshold:TECHnology............................................................................303
CHANnel<m>:THReshold:USER..................................................................................... 304
CHANnel<m>:THReshold:THReshold?............................................................................ 304
CHANnel<m>:THReshold:FINDlevel................................................................................ 304
CHANnel<m>:STATe <State>