Remote Control Commands
R&S
®
Scope Rider RTH
317User Manual 1326.1578.02 ─ 12
*RST: ALL
TRIGger:TV:LINE <LineNumber>
Sets the number of the line to be triggered on if TRIGger:TV:MODE is LINE.
Usually the lines of the frame are counted, beginning from the frame start.
For NTSC signals, the lines are counted per field, not per frame. Therefore, you have
to set the odd or even field using TRIGger:TV:LFIeld, and the line number in the
field.
Parameters:
<LineNumber> Range: 1 to 3000
Increment: 1
*RST: 1
TRIGger:TV:LFIeld
<LineField>
Line field (odd or even) used as reference for counting the video lines. Used by the
NTSC standard.
Parameters:
<LineField> FIELD1 | FIELD2
*RST: FIELD1
TRIGger:TV:CUSTom:STYPe <SyncPulseType>
Sets the type of the sync pulse, either bi-level sync pulse (usually used in SDTV sig-
nals), or tri-level sync pulse (used in HDTV signals).
Parameters:
<SyncPulseType> BILevel | TRILevel
*RST: BILevel
TRIGger:TV:CUSTom:LDURation <LineDuration>
Sets the duration of a single video line, the time between two successive sync pulses.
Parameters:
<LineDuration> Range: 5E-6 to 200E-6
Increment: 100E-9
*RST: 64E-6
Default unit: s
TRIGger:TV:CUSTom:SDURation <SyncPulseDuration>
Sets the width of the sync pulse.
Waveform Setup