Remote Control Commands
R&S
®
Scope Rider RTH
325User Manual 1326.1578.02 ─ 12
TRIGger:LEVel<m>:SLEW:LOWer <Level>
TRIGger:LEVel<m>:SLEW:UPPer <Level>
Set the upper and lower voltage thresholds, respectively. The time measurement starts
when the signal crosses the first trigger level - the upper or lower level depending on
the selected slope - and stops when the signal crosses the second level.
Suffix:
<m>
.
1..4
Indicates the trigger source: analog channel 1 to 4
Parameters:
<Level> Range: -10 to 10
Increment: 1E-3
*RST: 0
Default unit: V
TRIGger:SLEW:SLOPe
<Slope>
Sets the edge direction for the trigger.
Parameters:
<Slope> POSitive | NEGative | EITHer
*RST: POSitive
TRIGger:SLEW:RANGe <Condition>
Defines the time limits of the slew rate.
Parameters:
<Condition> LONGer | SHORter | EQUal | NEQual | WITHin | OUTSide
LONGer | SHORter
Triggers on pulses shorter or longer than a runt width that is set
using TRIGger:SLEW:RATE.
EQUal | NEQual
Triggers on pulses equal or not equal a given runt width that is
set using TRIGger:SLEW:RATE. In addition, a tolerance can be
set around the specified width using TRIGger:RUNT:DELTa.
WITHin | OUTSide
Triggers on pulses inside or outside a given range. The range is
set using ... and ....
*RST:
LONGer
TRIGger:SLEW:RATE <Duration>
Sets the slew rate for comparison ranges EQUal, UNEQual, SHORter, and LONGer.
See TRIGger:SLEW:RANGe.
Waveform Setup