EasyManua.ls Logo

Rohde & Schwarz Scope Rider RTH1004 - Page 399

Rohde & Schwarz Scope Rider RTH1004
530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
Scope Rider RTH
399User Manual 1326.1578.02 ─ 12
Suffix:
<m>
.
1..4
R&S RTH1002: always 1, omit the suffix
R&S RTH1004: Selects the voltmeter.
Parameters:
<CoupVoltageMeas> DCLimit | ACLimit
DCLimit
Enables AC+DC measurement.
ACLimit
Enables AC measurement.
*RST: DCLimit
Example: Configure and perform AC+DC current measurement with range
100 A:
:METer:CONFigure:CURRent:AC 100
:METer:SENSe:FUNCtion 'CURR:AC'
:METer:CONFigure:VALue?
<-- "CURR:AC 100"
:METer:SENSe:CURRent:AC:COUPling DCL
:METer:READ?
<-- 0.035906488794
Configure and perform AC voltage measurement with range 10
V:
:METer:CONFigure:VAOLTage:AC 10
:METer:SENSe:FUNCtion 'VOLT:AC'
:METer:CONFigure:VALue?
<-- "VOLT:AC 10"
:METer:SENSe:CURRent:AC:COUPling ACL
:METer:READ?
<-- 0.030006488794
15.8.3 Relative Measurements
To perform relative measurements, set the relevant
METer<m>:SENSe:<function>:NULL:STATe command to ON. By default, the refer-
ence value is 0. Alternatively, you can use METer<m>:SENSe:RELative:STATe.
To change the reference value, use the
METer<m>:SENSe:<function>:NULL:VALue command.
METer<m>:SENSe:CURRent:AC:NULL:STATe................................................................. 400
METer<m>:SENSe:CURRent:DC:NULL:STATe................................................................. 400
METer<m>:SENSe:VOLTage:AC:NULL:STATe.................................................................. 400
METer<m>:SENSe:VOLTage:DC:NULL:STATe..................................................................400
METer<m>:SENSe:NULL:STATe......................................................................................400
METer<m>:SENSe:RELative:STATe.................................................................................400
METer<m>:SENSe:CURRent:AC:NULL:VALue................................................................. 400
METer<m>:SENSe:CURRent:DC:NULL:VALue................................................................. 400