Remote Control Commands
R&S
®
Scope Rider RTH
421User Manual 1326.1578.02 ─ 12
LOGGer:ZOOM:SCALe <Zoom Scale>
Sets the time scale of the zoomed waveform.
Parameters:
<Zoom Scale> AUTO | S1 | S2 | S4 | S5 | S10 | S20 | S40 | M1 | M2 | M4 | M5 |
M10 | M20 | M40 | H1 | H2 | H4 | H5 | H10 | H20 | D1 | D2 | D4
LOGGer:ZOOM:POSition <Time>
Sets or returns the position of the left edge of the zoomed area in relation to the left
side of the display.
Return values:
<Time> List of values:
<Year>,<Month>,<Day>,<Hour>,<Minute>,<Second>,
<TenthsOfSecond>
Year, month, day, hour, minute, second, tenth of a second, for
example 2016,10,29,16,10,22,2
Example: After 5 hours of logging, you want to see the first sample in the
zoom. Therefore, you enter the start time as zoom position. If
you scale the zoom, the start position remains.
15.10.5 Logger Statistics
The suffix <m> specifies the measurement that is logged.
LOGGer:RECording:STARt?........................................................................................... 421
LOGGer:RECording:TOTal?............................................................................................ 422
LOGGer:MEASurement<m>:RESult:CURRentsampl?....................................................... 422
LOGGer:MEASurement<m>:RESult:MAXimum:POSition?................................................. 422
LOGGer:MEASurement<m>:RESult:MAXimum:VALue?.....................................................422
LOGGer:MEASurement<m>:RESult:MINimum:POSition?.................................................. 423
LOGGer:MEASurement<m>:RESult:MINimum:VALue?......................................................423
LOGGer:MEASurement<m>:RESult:MEAN?.....................................................................423
LOGGer:MEASurement<m>:RESult:STDDev?..................................................................423
LOGGer:MEASurement<m>:ENABled?............................................................................424
LOGGer:MEASurement<m>:TYPE?................................................................................ 424
LOGGer:MEASurement<m>:SOURce?............................................................................ 424
LOGGer:RECording:STARt?
Returns the absolute start time of the current logging session.
Return values:
<StartTime> Year, month, day, hour, minute, second, tenth of a second, for
example 2015,10,29,16,10,22,2
Usage: Query only