Remote Control Commands
R&S
®
Scope Rider RTH
441User Manual 1326.1578.02 ─ 12
BUS:SPI:FCOunt?
Returns the number of decoded frames.
Return values:
<Count> Total number of decoded frames.
Range: 0 to 100000
Increment: 1
*RST: 0
Usage: Query only
BUS:SPI:FRAMe<m>:DATA?
Returns the data words of the specified frame.
Suffix:
<m>
.
*
Selects the frame.
Parameters:
<Data> List of decimal values of data bytes
Example:
BUS:SPI:FRAM3:DATA?
<-- 94,177,171,60,242,219,100,0
Usage: Query only
BUS:SPI:FRAMe<m>:STATus?
Returns the overall status of the specified frame.
Suffix:
<m>
.
*
Selects the frame.
Return values:
<State> OK | VOID | FRERror | INSufficient
VOID: The frame is empty.
FRERror: error in the frame.
INSufficient: frame is not completely contained in the acqui-
sition. The acquired part of the frame is valid.
*RST: OK
Usage: Query only
BUS:SPI:FRAMe<m>:STARt?
Returns the start time of the specified frame.
Suffix:
<m>
.
*
Selects the frame.
Protocol Analysis