EasyManua.ls Logo

Rohde & Schwarz Scope Rider RTH1004 - Page 452

Rohde & Schwarz Scope Rider RTH1004
530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
Scope Rider RTH
452User Manual 1326.1578.02 ─ 12
BUS:CAN:DATA:THReshold <ThresholdValue>
Sets the threshold value for digitization of signals manually. If the signal value is higher
than the threshold, the signal state is high. Otherwise, the signal state is considered
low.
This value is only considered for BUS:CAN:TECHnology USER
Parameters:
<ThresholdValue> Range: -400 to 400
Increment: 1E-3
*RST: 1.4
Default unit: V
BUS:SETReflevels
Sets the appropriate threshold or threshold for the selected serial protocol.
Usage:
Event
BUS:CAN:SAMPlepoint <SamplePoint>
The sample point divides the nominal bit period into two distinct time segments. The
length of the time segments is defined in time quanta according to network and node
conditions during CAN development.
Parameters:
<SamplePoint> Range: 10 to 95
Increment: 1
*RST: 50
Default unit: %
BUS:CAN:FDATa:ABITrate <ArbCustomBitrate>
Sets the bit rate of the arbitration phase of the CAN FD bus.
The setting is available in CAN FD option R&S RTH-K9.
Parameters:
<ArbCustomBitrate> Range: 10000 to 1000000
Increment: 1
*RST: 50000
Default unit: bps
BUS:CAN:FDATa:ASAMplepoint <ArbSamplePoint>
The sample point divides the arbitration phase into two distinct time segments. The
length of the time segments is defined in time quanta according to network and node
conditions during CAN FD development.
The setting is available in CAN FD option R&S RTH-K9.
Protocol Analysis

Table of Contents

Other manuals for Rohde & Schwarz Scope Rider RTH1004

Related product manuals