EasyManua.ls Logo

Rohde & Schwarz Scope Rider RTH1004 - Page 473

Rohde & Schwarz Scope Rider RTH1004
530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
Scope Rider RTH
473User Manual 1326.1578.02 ─ 12
Return values:
<IdentifierValue> Range: 0 to 63
*RST: 0
Usage: Query only
BUS:LIN:FRAMe<m>:STARt?
BUS:LIN:FRAMe<m>:STOP?
Returns the start time and stop time of the selected frame, respectively.
Suffix:
<m>
.
*
Return values:
<FrameStart>
<FrameStop>
Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
BUS:LIN:FRAMe<m>:STATus?
Returns the overall state of the selected frame.
Suffix:
<m>
.
*
Return values:
<FrameState> OK | WAKeup | SYERror | PRERror | CHCKsum | CPERror |
INSufficient
CHCKsum: checksum error
PRERror: parity error in identifier
SYERror: synchronization error
WAKeup: the frame is a wakeup frame
CPERror: parity error and checksum error
INSufficient: the frame is not completely contained in the acqui-
sition. The decoded part of the frame is valid.
*RST: OK
Usage: Query only
BUS:LIN:FRAMe<m>:SYMBol?
Returns the symbolic label of the specified frame if the label list is enabled.
Suffix:
<m>
.
*
Return values:
<Label> String with symbolic name of the identifier