EasyManua.ls Logo

Rohde & Schwarz Scope Rider RTH1004 - Page 65

Rohde & Schwarz Scope Rider RTH1004
530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Waveform Setup
R&S
®
Scope Rider RTH
65User Manual 1326.1578.02 ─ 12
Remote command:
TRIGger:STATe:CSOurce:EDGE on page 322
Set Pattern
Defines the pattern: the states of the input channels and their logical combination. If
R&S RTH-B1 is installed, active digital channels are also included in the pattern defini-
tion.
For details, see Chapter 3.6.7, "Pattern Trigger (R&S RTH-K19)", on page 62.
Remote command:
TRIGger:STATe:CHANnel<m> on page 321
TRIGger:STATe:COMBination on page 322
3.6.9 Runt Trigger (R&S RTH-K19)
A runt is a pulse lower than normal in amplitude. The amplitude crosses the first level
twice in succession without crossing the second one. In addition to the upper and lower
levels, you can define a time limit for the runt in the same way as for width triggers. For
example, the runt trigger can detect signal parts remaining below a specified threshold
amplitude because I/O ports are in undefined state.
UL
L L
Figure 3-14: Runt trigger without time limits
[SETUP] key > "Trigger Type" = "Runt"
Description of settings
Trigger

Table of Contents

Other manuals for Rohde & Schwarz Scope Rider RTH1004

Related product manuals