Remote Control Commands
R&S
®
SGS100A
237User Manual 1173.9105.02 ─ 12
Parameters:
<Source> INTernal | EXTernal
INT: use built in oscillator; EXT: use signal at [REF/LO IN] con-
nector
Example: See Chapter 11.1.2, "Generating an I/Q Modulated Signal",
on page 193.
Manual operation: See "Source" on page 83
[:SOURce]:PATH:COUNt?
Queries the number of installed RF paths.
Return values:
<Count> integer
Range: 1 to INT_MAX
*RST: 1
Example:
PATH:COUN?
Queries the number of RF paths.
Response: 1
The instrument is equipped with one RF path.
Usage: Query only
11.14 SOURce:CORRection Subsystem
The output level is corrected in the CORRection subsystem. Correction is performed
by user-defined table values being added to the output level for the respective RF fre-
quency. In the R&S SGS, this subsystem is used to select, transfer and activate user
correction tables.
Each list is stored as a file. The name of the user correction file can be freely selected.
The file extension *.uco is assigned automatically and cannot be changed.
The files can be stored in a freely selectable directory and opened from there. The
default directory is set using command :MMEMory:CDIRectory on page 216. In the
case of files which are stored in the default directory, only the file name has to be
specified in commands. Otherwise, the complete absolute path has to be specified with
every command. The extension can be omitted in any case.
In the following command examples, the files are stored in the default directory.
[:SOURce]:CORRection:CSET:CATalog?..........................................................................238
[:SOURce<hw>]:CORRection:CSET:DATA:FREQuency.....................................................238
[:SOURce<hw>]:CORRection:CSET:DATA:FREQuency:POINts?........................................239
[:SOURce<hw>]:CORRection:CSET:DATA:POWer............................................................239