Signal Generator Settings
R&S
®
SGS100A
81User Manual 1173.9105.02 ─ 12
Access:
Select "SGMA-GUI > Instrument Name > Frequency/Phase".
The frequency and phase related settings are provided in this dialog.
Configuring the RF frequency
1. To change the RF frequency of the selected instrument, perform one of the follow-
ing:
a) Select "SGMA-GUI > Instrument Name > Frequency/Phase > Frequency" and
set the frequency at the RF output.
b) Select "SGMA-GUI main panel > Freq" and set the frequency.
The value includes possible frequency offset.
2. To enable frequency offset for example to consider the frequency shift of a down-
stream instrument, set the parameter "Frequency/Phase > Offset".
Changes of the RF frequency have an immediate effect on the output signal.
Frequency
Sets the RF frequency at the RF output connector of the selected instrument.
The displayed value does not consider an enabled frequency offset (Offset).
Remote command:
See [:SOURce]:FREQuency[:CW|FIXed] on page 236
Offset
Sets a frequency offset.
The frequency offset value represents the frequency shift of a downstream instrument,
as for example an attenuator or an amplifier.
Enabled frequency offset does not change the frequency at the RF output (Frequency).
It influences the value of the parameter "SGMA-GUI main panel > Freq".
The following applies:
"Freq" = Frequency + "Offset"
Frequency/Phase Settings