Remote Control Commands
R&S
®
SMA100B
428User Manual 1178.3834.02 ─ 05
Parameters:
<Offset> float
Range: -5 to 5
Increment: 0.001
*RST: 0
Example: See Chapter 13.7, "CSYNthesis Subsystem", on page 425.
Manual operation: See " DC Offset " on page 281
:CSYNthesis:VOLTage <Voltage>
Sets the voltage for the CMOS signal.
Parameters:
<Voltage> float
Range: 0.8 to 2.7
Increment: 0.001
*RST: 1.8
Example:
CSYNthesis:OTYPe CMOS
CSYNthesis:VOLTage 1.8
CSYNthesis:FREQuency 100000000
CSYNthesis:STATe 1
Manual operation: See "Voltage" on page 281
:CSYNthesis:PHASe <Phase>
Shifts the phase of the generated clock signal.
Parameters:
<Phase> float
Range: -36000 to 36000
Increment: 0.1
*RST: 0
Example: See Chapter 13.7, "CSYNthesis Subsystem", on page 425.
Manual operation: See "Delta Phase" on page 281
:CSYNthesis:PHASe:REFerence
Resets the delta phase value.
Example:
See Chapter 13.7, "CSYNthesis Subsystem", on page 425.
Usage: Event
CSYNthesis Subsystem