Remote Control Commands
R&S
®
SMA100B
560User Manual 1178.3834.02 ─ 05
[:SOURce<hw>]:ILS:LOCalizer:COMid:CODE <Code>
Sets the coding of the COM/ID signal by the international short name of the airport
(e.g. MUC for the Munich airport).
The COM/ID tone is sent according to the selected code, see Chapter D, "Morse Code
Settings", on page 740.
If no coding is set, the COM/ID tone is sent uncoded (key down).
Parameters:
<Code> string
Example: See Example "Configure and generate an ILS localizer signal"
on page 543.
Manual operation: See "Code" on page 142
[:SOURce<hw>]:ILS:LOCalizer:COMid:DASH <Dash>
Sets the length of a Morse code dash.
Parameters:
<Dash> float
Range: 0.05 to 1
Increment: 1E-4
*RST: 0.3
Example: See Example "Configure and generate an ILS localizer signal"
on page 543.
Manual operation: See " Dash Length " on page 143
[:SOURce<hw>]:ILS:LOCalizer:COMid:DEPTh <Depth>
Sets the AM modulation depth of the COM/ID signal.
Parameters:
<Depth> float
Range: 0 to 100
Increment: 0.1
*RST: 10
Example: See Example "Configure and generate an ILS localizer signal"
on page 543.
Manual operation: See "Depth" on page 142
[:SOURce<hw>]:ILS:LOCalizer:COMid:DOT <Dot>
Sets the length of a Morse code dot.
SOURce Subsystem