Remote Control Commands
R&S
®
SMA100B
561User Manual 1178.3834.02 ─ 05
Parameters:
<Dot> float
Range: 0.05 to 1
Increment: 1E-4
*RST: 0.1
Example: See Example "Configure and generate an ILS localizer signal"
on page 543.
Manual operation: See "Dot Length" on page 143
[:SOURce<hw>]:ILS:LOCalizer:COMid:FREQuency
<Frequency>
Sets the frequency of the COM/ID signal.
Parameters:
<Frequency> float
Range: 0.1 to 20E3
Increment: 0.01
*RST: 1020
Example: See Example "Configure and generate an ILS localizer signal"
on page 543.
Manual operation: See "Frequency" on page 142
[:SOURce<hw>]:ILS:LOCalizer:COMid:LETTer <Letter>
Sets the length of a Morse code letter space.
Parameters:
<Letter> float
Range: 0.05 to 1
Increment: 1E-4
*RST: 0.3
Example: See Example "Configure and generate an ILS localizer signal"
on page 543.
Manual operation: See " Letter Space " on page 143
[:SOURce<hw>]:ILS:LOCalizer:COMid:PERiod <Period>
Sets the period of the COM/ID signal.
Parameters:
<Period> float
Range: 0 to 120
Increment: 1E-3
*RST: 9