EasyManua.ls Logo

Rohde & Schwarz SMAB-B92 - Source:correction Subsystem

Rohde & Schwarz SMAB-B92
778 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMA100B
582User Manual 1178.3834.02 ─ 05
Parameters:
<Frequency> float
Range: 5E3 to 15E3
Increment: 0.01
*RST: 9.96E3
Example: See Example "Configure and generate a VOR signal"
on page 544.
Manual operation: See "Subcarrier Frequency" on page 120
[:SOURce<hw>]:VOR:VAR:FREQuency
<Frequency>
Sets the frequency of the variable and the reference signal. As the two signals must
have the same frequency, the setting is valid for both signals.
Parameters:
<Frequency> float
Range: 10 to 60
Increment: 0.01
*RST: 30
Example: See Example "Configure and generate a VOR signal"
on page 544.
Manual operation: See "VAR/REF Frequency" on page 120
[:SOURce<hw>]:VOR:VAR[:DEPTh] <Depth>
Sets the AM modulation depth of the 30Hz variable signal.
Parameters:
<Depth> float
Range: 0 to 100
Increment: 0.1
*RST: 30
Example: See Example "Configure and generate a VOR signal"
on page 544.
Manual operation: See "VAR Depth" on page 120
13.16.3 SOURce:CORRection Subsystem
The SOURce:CORRection subsystem contains the commands for defining correction
values for external test assemblies.
You can acquire the correction values any time, regardless of the modulation settings
of the generator. The correction is performed by adding the correction values to the
output level of the respective RF frequency.
SOURce Subsystem

Table of Contents