Remote Control Commands
R&S
®
SMA100B
645User Manual 1178.3834.02 ─ 05
// Input the frequency manually for each step
SOURce1:FREQuency:MANual 200 MHz
SOURce1:FREQuency:MANual 201 MHz
// Alternatively use the UP or DOWN commands with the set step width.
SOURce1:SWEep:FREQuency:STEP:LINear 1 MHz
SOURce1:FREQuency:MANual UP
:SWEep:TYPE...............................................................................................................645
[:SOURce<hw>]:SWEep:POWer:DWELl...........................................................................645
[:SOURce<hw>]:SWEep:GENeration............................................................................... 646
[:SOURce<hw>]:SWEep:POWer:MODE...........................................................................646
[:SOURce<hw>]:SWEep:POWer:POINts.......................................................................... 647
[:SOURce<hw>]:SWEep:POWer:SPACing:MODE?........................................................... 647
[:SOURce<hw>]:SWEep:POWer:STEP[:LOGarithmic]....................................................... 647
[:SOURce<hw>]:SWEep[:FREQuency]:DWELl..................................................................648
[:SOURce<hw>]:SWEep[:FREQuency]:MODE..................................................................648
[:SOURce<hw>]:SWEep[:FREQuency]:POINts................................................................. 648
[:SOURce<hw>]:SWEep[:FREQuency]:SPACing...............................................................649
[:SOURce<hw>]:SWEep:POWer:SHAPe..........................................................................649
[:SOURce<hw>]:SWEep[:FREQuency]:SHAPe................................................................. 649
[:SOURce<hw>]:SWEep:POWer:EXECute....................................................................... 650
[:SOURce<hw>]:SWEep[:FREQuency]:EXECute.............................................................. 650
[:SOURce<hw>]:SWEep:POWer:RETRace.......................................................................650
[:SOURce<hw>]:SWEep[:FREQuency]:RETRace..............................................................650
[:SOURce<hw>]:SWEep:POWer:RUNNing?..................................................................... 650
[:SOURce<hw>]:SWEep[:FREQuency]:RUNNing?............................................................ 650
[:SOURce<hw>]:SWEep[:FREQuency]:STEP:LOGarithmic................................................ 650
[:SOURce<hw>]:SWEep[:FREQuency]:STEP[:LINear].......................................................651
[:SOURce<hw>]:SWEep:RESet[:ALL].............................................................................. 651
[:SOURce<hw>]:SWEep[:FREQuency]:TIME....................................................................651
[:SOURce<hw>]:SWEep:MARKer:OUTPut:POLarity..........................................................652
[:SOURce<hw>]:SWEep[:FREQuency]:MARKer:ACTive.................................................... 652
[:SOURce<hw>]:SWEep[:FREQuency]:MARKer<ch>:FREQuency......................................652
[:SOURce<hw>]:SWEep[:FREQuency]:MARKer<ch>:FSTate............................................. 653
:SWEep:TYPE <SweepType>
Provided for compatibility between SCPI and Rohde & Schwarz commands.
Parameters:
<SweepType> ADVanced | STANdard
*RST: n.a. (factory preset: STANdard)
[:SOURce<hw>]:SWEep:POWer:DWELl <Dwell>
Sets the dwell time for a level sweep step.
SOURce Subsystem