EasyManua.ls Logo

Rohde & Schwarz SMAB-B92 - Page 647

Rohde & Schwarz SMAB-B92
778 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMA100B
645User Manual 1178.3834.02 ─ 05
// Input the frequency manually for each step
SOURce1:FREQuency:MANual 200 MHz
SOURce1:FREQuency:MANual 201 MHz
// Alternatively use the UP or DOWN commands with the set step width.
SOURce1:SWEep:FREQuency:STEP:LINear 1 MHz
SOURce1:FREQuency:MANual UP
:SWEep:TYPE...............................................................................................................645
[:SOURce<hw>]:SWEep:POWer:DWELl...........................................................................645
[:SOURce<hw>]:SWEep:GENeration............................................................................... 646
[:SOURce<hw>]:SWEep:POWer:MODE...........................................................................646
[:SOURce<hw>]:SWEep:POWer:POINts.......................................................................... 647
[:SOURce<hw>]:SWEep:POWer:SPACing:MODE?........................................................... 647
[:SOURce<hw>]:SWEep:POWer:STEP[:LOGarithmic]....................................................... 647
[:SOURce<hw>]:SWEep[:FREQuency]:DWELl..................................................................648
[:SOURce<hw>]:SWEep[:FREQuency]:MODE..................................................................648
[:SOURce<hw>]:SWEep[:FREQuency]:POINts................................................................. 648
[:SOURce<hw>]:SWEep[:FREQuency]:SPACing...............................................................649
[:SOURce<hw>]:SWEep:POWer:SHAPe..........................................................................649
[:SOURce<hw>]:SWEep[:FREQuency]:SHAPe................................................................. 649
[:SOURce<hw>]:SWEep:POWer:EXECute....................................................................... 650
[:SOURce<hw>]:SWEep[:FREQuency]:EXECute.............................................................. 650
[:SOURce<hw>]:SWEep:POWer:RETRace.......................................................................650
[:SOURce<hw>]:SWEep[:FREQuency]:RETRace..............................................................650
[:SOURce<hw>]:SWEep:POWer:RUNNing?..................................................................... 650
[:SOURce<hw>]:SWEep[:FREQuency]:RUNNing?............................................................ 650
[:SOURce<hw>]:SWEep[:FREQuency]:STEP:LOGarithmic................................................ 650
[:SOURce<hw>]:SWEep[:FREQuency]:STEP[:LINear].......................................................651
[:SOURce<hw>]:SWEep:RESet[:ALL].............................................................................. 651
[:SOURce<hw>]:SWEep[:FREQuency]:TIME....................................................................651
[:SOURce<hw>]:SWEep:MARKer:OUTPut:POLarity..........................................................652
[:SOURce<hw>]:SWEep[:FREQuency]:MARKer:ACTive.................................................... 652
[:SOURce<hw>]:SWEep[:FREQuency]:MARKer<ch>:FREQuency......................................652
[:SOURce<hw>]:SWEep[:FREQuency]:MARKer<ch>:FSTate............................................. 653
:SWEep:TYPE <SweepType>
Provided for compatibility between SCPI and Rohde & Schwarz commands.
Parameters:
<SweepType> ADVanced | STANdard
*RST: n.a. (factory preset: STANdard)
[:SOURce<hw>]:SWEep:POWer:DWELl <Dwell>
Sets the dwell time for a level sweep step.
SOURce Subsystem