Remote Control Commands
R&S
®
SMA100B
656User Manual 1178.3834.02 ─ 05
:SYSTem:LANGuage......................................................................................................669
:SYSTem:INFormation:SCPI............................................................................................669
:SYSTem:SECurity:SANitize[:STATe]................................................................................670
:SYSTem:SECurity:SUPolicy........................................................................................... 670
:SYSTem:SPECification?................................................................................................ 670
:SYSTem:SPECification:VERSion....................................................................................671
:SYSTem:SPECification:IDENtification:CATalog?...............................................................671
:SYSTem:SPECification:PARameter?...............................................................................672
:SYSTem:SPECification:VERSion:CATalog?..................................................................... 672
:SYSTem:SPECification:VERSion:FACTory?.....................................................................672
:SYSTem:SRData?.........................................................................................................673
:SYSTem:STARtup:COMPlete?....................................................................................... 673
:SYSTem:DATE............................................................................................................. 673
:SYSTem:NTP:HOSTname............................................................................................. 674
:SYSTem:NTP:STATe..................................................................................................... 674
:SYSTem:TIME.............................................................................................................. 674
:SYSTem:TIME:ZONE.................................................................................................... 675
:SYSTem:TIME:ZONE:CATalog?......................................................................................675
:SYSTem:UPTime?........................................................................................................ 675
:SYSTem:BIOS:VERSion?.............................................................................................. 675
:SYSTem:VERSion?.......................................................................................................675
:SYSTem:OSYStem?......................................................................................................676
:SYSTem:MMEMory:PATH:USER?.................................................................................. 676
:SYSTem:DFPR?........................................................................................................... 676
:SYSTem:REBoot...........................................................................................................676
:SYSTem:RESTart..........................................................................................................677
:SYSTem:SHUTdown..................................................................................................... 677
:SYSTem:WAIT..............................................................................................................677
:SYSTem:FILes:TEMPorary:DELete.................................................................................677
:SYSTem:ERRor:ALL?
Queries the error/event queue for all unread items and removes them from the queue.
Return values:
<All> string
Error/event_number,"Error/event_description>[;Device-depend-
ent info]"
A comma separated list of error number and a short description
of the error in FIFO order.
If the queue is empty, the response is 0,"No error"
Positive error numbers are instrument-dependent. Negative
error numbers are reserved by the SCPI standard.
Volatile errors are reported once, at the time they appear. Identi-
cal errors are reported repeatedly only if the original error has
already been retrieved from (and hence not any more present in)
the error queue.
SYSTem Subsystem