Remote Control Commands
R&S
®
SMA100B
444User Manual 1178.3834.02 ─ 05
Parameters:
<Layout> CHINese | DANish | DUTCh | DUTBe | ENGLish | ENGUK |
FINNish | FRENch | FREBe | FRECa | GERMan | ITALian |
JAPanese | KORean | NORWegian | PORTuguese | RUSSian |
SPANish | SWEDish | ENGUS
*RST: n.a. (factory preset: ENGLish)
Example:
:KBOard:LAYout US
// activates American keyboard
Manual operation: See "USB Keyboard > Layout" on page 319
13.13 OUTPut Subsystem
In the OUTPut subsystem, you can configure the output signals.
The LF output signal is defined with the commands of the Chapter 13.16.6,
"SOURce:LFOutput Subsystem", on page 599 system.
Common suffixes
The following common suffixes are used in remote commands:
Suffix Value range Description
OUTPut<hw>
[1] Optional suffix
:OUTPut:ALL[:STATe]..................................................................................................... 444
:OUTPut<hw>[:STATe]....................................................................................................445
:OUTPut<hw>[:STATe]:PON............................................................................................445
:OUTPut<hw>:AMODe................................................................................................... 445
:OUTPut<hw>:FILTer:MODE........................................................................................... 446
:OUTPut<hw>:IMPedance?.............................................................................................446
:OUTPut:FPRoportional:SCALe.......................................................................................446
:OUTPut:USER:MARKer.................................................................................................447
:OUTPut<hw>:AFIXed:RANGe:LOWer?...........................................................................447
:OUTPut<hw>:AFIXed:RANGe:UPPer?............................................................................447
:OUTPut<hw>:PROTection:CLEar................................................................................... 447
:OUTPut<hw>:PROTection:TRIPped?.............................................................................. 448
:OUTPut:ALL[:STATe] <State>
Activates the RF output signal of the instrument.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 0)
Example:
OUTPut:ALL:STATe 0