Remote Control Commands
R&S
®
SMA100B
445User Manual 1178.3834.02 ─ 05
:OUTPut<hw>[:STATe] <State>
Activates the RF output signal.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
OUTP ON
Activates the RF output.
Manual operation: See "RF State/RF ON" on page 62
:OUTPut<hw>[:STATe]:PON <Pon>
Defines the state of the RF output signal when the instrument is switched on.
Parameters:
<Pon> OFF | UNCHanged
*RST: n.a. (factory preset: UNCHanged)
Example:
OUTP:PON OFF
The RF output is deactivated when the instrument is switched
on.
Manual operation: See " Power-On State " on page 320
:OUTPut<hw>:AMODe <AMode>
Sets the step attenuator mode at the RF output.
Parameters:
<AMode> AUTO | FIXed
AUTO
The step attenuator adjusts the level settings automatically,
within the full variation range.
FIXed
The step attenuator and amplifier stages are fixed at the current
position, providing level settings settings with constant output
VSWR. The resulting variation range is calculated according to
the position.
*RST: AUTO
Example:
SOURce:POWer:ALC:STATe 1
OUTPut:AMODe FIXed
Manual operation: See " Mode " on page 195