Remote Control Commands
R&S
®
SMA100B
660User Manual 1178.3834.02 ─ 05
DONLy
Locks the touchscreen and controls for the manual operation of
the instrument. The display shows the current settings.
VNConly
Locks the touchscreen and controls for the manual operation,
and enables remote operation over VNC. The display shows the
current settings.
TOFF
Locks the touchscreen for the manual operation of the instru-
ment. The display shows the current settings.
DISabled
Locks the display, the touchscreen and all controls for the man-
ual operation.
*RST:
n.a. (factory preset: ENABled)
Example:
:SYST:ULOC DIS
Activates the user interface lock, including display and controls.
Manual operation: See "User Interface" on page 338
:SYSTem:DLOCk <DispLockStat>
Disables the manual operation via the display, including the front panel keyboard of the
instrument and the Local key.
Parameters:
<DispLockStat> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 0)
Example:
SYST:DLOC ON
Activates the display lock. The instrument cannot be operated
via the display until it has been enabled with SYST:DLOC OFF.
Manual operation: See "User Interface" on page 338
:SYSTem:KLOCk <State>
Disables the front panel keyboard of the instrument including the Local key.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 0)
Example:
SYST:KLOC ON
Locks the front panel and external controls.
To enable the controls, send SYST:KLOC OFF.
Manual operation: See "User Interface" on page 338