Remote Control Commands
R&S
®
SMA100B
678User Manual 1178.3834.02 ─ 05
Value ranges
Queries return the current value of the respective register, which permits a check of
the device status.
Return values: A decimal value in the range 0 to 32767 (=2
15
-1)
The configuration commands set the respective register thus determining which
status changes of the R&S SMA100B cause the status registers to be changed.
Setting values: A decimal value in the range 0 to 32767 (=2
15
-1)
:STATus:OPERation:CONDition?.....................................................................................678
:STATus:OPERation:ENABle...........................................................................................678
:STATus:OPERation[:EVENt]...........................................................................................679
:STATus:OPERation:NTRansition.................................................................................... 679
:STATus:OPERation:PTRansition.....................................................................................679
:STATus:PRESet............................................................................................................679
:STATus:QUEStionable:CONDition.................................................................................. 680
:STATus:QUEStionable:ENABle.......................................................................................680
:STATus:QUEStionable[:EVENt]...................................................................................... 680
:STATus:QUEStionable:NTRansition................................................................................680
:STATus:QUEStionable:PTRansition................................................................................ 681
:STATus:QUEue[:NEXT]?................................................................................................681
:STATus:OPERation:CONDition?
Quieries the content of the CONDition part of the STATus:OPERation register.
This part contains information on the action currently being performed in the instru-
ment. The content is not deleted after being read out because it indicates the current
hardware status.
Return values:
<Condition> string
Example:
:STATus:OPERation:CONDition?
Usage: Query only
:STATus:OPERation:ENABle <Enable>
Sets the bits of the ENABle part of the STATus:OPERation register. This setting deter-
mines which events of the Status-Event part are forwarded to the sum bit in the status
byte. These events can be used for a service request.
Parameters:
<Enable> string
Example:
:STAT:OPER:ENAB 32767
all events are forwarded to the sum bit of the status byte.
STATus Subsystem