Instrument Function
R&S
®
SMBV100A
413Operating Manual 1176.8016.02 ─ 17
The triangle on the top line denotes a trigger event. A filled triangle on the bottom
line denotes a next segment event.
A green sinewave (or other shape) over a full period indicates one replay cycle of a
segment ; A shorter example signal indicates a replay cycle which was interrupted,
e.g. due to a next segment event (compare the two graphics in Table 5-13).
Table 5-13: Trigger examples in the "ARB" dialog
"Next Segment Mode = Next Segment" "Next Segment Mode = Next Segment Seamless"
Multi Segment Waveform Settings
To access the "Multi Segment" dialog, select "Baseband > ARB > Multi Segment...".
Example
How to create multi segment waveform file
1. Select "New List" to create empty list.
2. Use the "Append" function to add two or more waveform files.
3. Adjust the "Level", "Clock" and "Segment Marker" settings.
4. Select the "Output File" and enter file name.
5. Select "Save List" to save the configuration.
6. Select "Create" or "Create and Load" to create and save the multi segment wave-
form.