Instrument Function
R&S
®
SMBV100A
444Operating Manual 1176.8016.02 ─ 17
The "Marker Delay" section is where a marker signal delay can be defined, either with-
out restriction or restricted to the dynamic section, i.e., the section in which it is possi-
ble to make settings without restarting signal and marker generation.
The "Clock Settings" section is where the clock source is selected and - in the case of
an external source - the clock type.
The buttons in the last section lead to submenu for general trigger, clock and mapping
settings.
Trigger In
The "Trigger In" section is where the trigger for the signal is set. Various parameters
will be provided for the settings, depending on which trigger source - internal or exter-
nal - is selected. The current status of signal generation ("Running" or "Stopped") is
indicated for all trigger modes.
Trigger Mode
Selects trigger mode.
The trigger mode determines the effect of a trigger on the signal generation.
"Auto"
The signal is generated continuously.
Baseband Signal - Baseband Block