EasyManua.ls Logo

Rohde & Schwarz SMBV100A - Page 646

Rohde & Schwarz SMBV100A
911 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMBV100A
631Operating Manual 1176.8016.02 ─ 17
Manual operation: See "File Size" on page 431
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:CATalog?
Queries the available settings files in the specified default directory. The settings files
are used to set the ARB multi carrier submenu. Only files with the file extension
*.arb_multcarr will be listed.
Return values:
<Catalog> string
Example:
MMEM:CDIR '/var/user/waveform'
sets the default directory
BB:ARB:MCAR:SETT:CAT?
reads out all the settings files in the default directory.
Response: mcar1, mcar2
the directory contains the configuration files
mcar1.arb_multcarr and mcar2.arb_multcarr.
Usage: Query only
Manual operation: See "Save/Recall Frame" on page 425
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:LOAD <Filename>
Loads the settings file. If a settings file with the specified name does not yet exist, it is
created. The file extension may be omitted. Only files with the file extension
*.arb_multcarr will be loaded or created.
Setting parameters:
<Filename> string
Example:
BB:ARB:MCAR:SETT:LOAD '/var/user/new'
creates settings file new.arb_multcarr.
Usage: Setting only
Manual operation: See "Save/Recall Frame" on page 425
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:STORe <Filename>
The command stores the current settings of submenu "Multi Carrier" in a file in the
specified directory. The file extension may be omitted, the files are stored with the file
extension *.arb_multcarr.
Setting parameters:
<Filename> string
Example:
BB:ARB:MCAR:SETT:STOR '/var/user/mcarr2'
stores settings file mcarr2.arb_multcarr in the default direc-
tory.
Usage: Setting only
SOURce Subsystem