Remote Control Commands
R&S
®
SMBV100A
666Operating Manual 1176.8016.02 ─ 17
<PGauss> float
Range: 0.15 to 2.5
Increment: 0.01
*RST: 0.3
<RCosine> float
Range: 0.05 to 1.00
Increment: 0.01
*RST: 0.35
<SPhase> float
Range: 0.15 to 2.5
Increment: 0.01
*RST: 2
Example:
BB:DM:FILT:PAR:APCO25 0.2
sets the roll-off factor to 0.2 for filter type APCO25.
Manual operation: See "Filter Parameter" on page 360
[:SOURce<hw>]:BB:DM:FILTer:PARameter:COSine:BANDwidth <FiltParm>
Sets the bandwidth of the cosine filter.
Parameters:
<FiltParm> float
Range: 400 to 25E6
Increment: 1E-3
*RST: 270833.333
Example:
:BB:DM:FILT:TYPE COS
:BB:DM:FILT:PAR:COS:BAND 7200
Manual operation: See "Bandwidth" on page 360
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25Lsm:GAUSs <FiltParm>
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25Lsm:LOWPass <FiltParm>
Sets the cut off frequency for the lowpass/ gauss filter.
Parameters:
<FiltParm> float
Range: 400 to 25E6
Increment: 1E-3
*RST: 270833.333
Example:
:BB:DM:FILT:TYPE APCO25Lsm
:BB:DM:FILT:PAR:APCO25L:LOWP 5166.667
:BB:DM:FILT:PAR:APCO25L:GAUS 1700
Manual operation: See "Cut Off Frequency Factor" on page 360