[:SOURce<hw>]:BB:DM:FLISt:POINts?
Queries the user filter list length.
Return values:
<Points> integer
Range: 0 to INT_MAX
*RST: 0
Example:
BB:DM:FILT:TYPE USER
selects the User filter type.
BB:DM:FLIS:POIN?
queries the list length.
Usage: Query only
[:SOURce<hw>]:BB:DM:FLISt:SELect <Filename>
Selects the user-defined filter (*.vaf).
The directory applicable to the following command is defined with the command
MMEM:CDIRectory. To access the files in this directory, only the file name is required,
without the path and the file extension.
Parameters:
<Filename> string
Example:
BB:DM:FILT:TYPE USER
selects the User filter type.
MMEM:CDIR '/var/user/Filter_List'
sets the default directory for the user-defined filters.
BB:DM:FLIS:SEL user_filter3
selects the user-defined filter.
Manual operation: See "Load User Filter" on page 361
[:SOURce<hw>]:BB:DM:MLISt:DELete <Filename>
Deletes the secified user mapping file. The default directory is set using command
MMEM:CDIRectory. A path can also be specified, in which case the files in the speci-
fied directory are read. The file extension may be omitted. Only files with the file exten-
sion *.vam will be deleted.
Setting parameters:
<Filename> string
Example:
BB:DM:FORM USER
selects the User modulation type.
MMEM:CDIR '/var/user/mapping_List'
sets the default directory for the user mapping lists.
BB:DM:MLIS:DEL user_mapping3
deletes the user mapping list.
Usage: Setting only