Configuring the Internal Baseband Source
R&S
®
SMBV100B
155User Manual 1178.4460.02 ─ 03
3.6.3.2 Sine Test Signals
Access:
► Select "Baseband > ARB > General > Create Test Signal > Sine" and press "Cre-
ate Test Signal".
This dialog provides settings for configuration of a sinusoidal test signal. A sine
wave is generated on the I path, and a sine wave of the same frequency but
phase-shifted is generated on the Q path. For more information, refer to Chap-
ter 3.6.2.2, "ARB Test Signals", on page 147.
The dialog displays the characteristic of the currently selected signal.
Settings:
Frequency................................................................................................................... 155
Samples per Period.....................................................................................................155
Phase Offset Q............................................................................................................156
Generate Signal File................................................................................................... 156
Generate Signal RAM................................................................................................. 156
Frequency
Enters the frequency of the test signal.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:SINE:FREQuency on page 748
Samples per Period
Enters the number of sample values required from the sine wave per period.
The maximum allowed value is determined by the maximum ARB clock rate (see data
sheet) and the selected frequency.
Using the Arbitrary Waveform Generator (ARB)