EasyManua.ls Logo

Rohde & Schwarz SMBV100B - Page 60

Rohde & Schwarz SMBV100B
1030 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Getting Started
R&S
®
SMBV100B
58User Manual 1178.4460.02 ─ 03
Figure 2-8: Signal mapping to the global connectors
The "Global Connectors" dialog displays the current connectors configuration. The
settings are configurable, but in this example we use the default mapping.
3. Alternatively, select "Block Diagram > Baseband > Misc > Custom Digital Mod",
select the "Trigger In" tab and select "Global Connector Settings".
In the current mapping, the two global connectors User x on the front panel are
configured as follows:
"Marker 1/2" are output at the User 1/2 connectors
The User 3 connector is an input for the "Global Trigger" signal.
Find the physical location of each connector
Use the built-in "Trigger Marker Clock > Show " function to display the location of the
selected connector. A blinking marker on the front/rear panel view also indicates the
selected connector.
To reconfigure the trigger settings
We assume that the instrument is configured as described in Chapter 2.3.2, "Generat-
ing a Digitally Modulated Signal", on page 53 and the default connector mapping is
maintained (see Figure 2-8).
1. In the block diagram, select "Baseband > Misc > Custom Digital Mod > Trigger In".
2. Select the following settings:
a) "Mode > Armed Auto"
b) "Source > External Global Trigger".
Trying Out the Instrument

Table of Contents

Related product manuals