SCONfiguration:EXTernal:IQOutput:DIRection?
// SCONfiguration:EXTernal:DIGital:IQConnection:STATe?
SCONfiguration:EXTernal:REMote:LIST?
// Response: SMBV100A,SGS_2,SGT100A,SMBV_1
SCONfiguration:EXTernal:REMote:ADD "SGS_1","USB","100007"
SCONfiguration:EXTernal:REMote:ADD "SGT100A","LAN","10.112.11.125","1"
SCONfiguration:EXTernal:REMote:LIST?
SCONfiguration:EXTernal:REMote:REName "SGS_2","SGS (102030)"
SCONfiguration:EXTernal:REMote:LIST?
// Response:
// SMBV100A,SGS (102030),SGT100A,SMBV_1
// Detecting a connected external instrument and connecting it
// SCONfiguration:EXTernal:DIGital:REMote:DETect?
// Response: "SMBV100A"
SCONfiguration:EXTernal:IQOutput:REMote:ISELect?
// Response: "SGT100A","A"
SCONfiguration:EXTernal:IQOutput:REMote:CONNect
// Manually defining the externa instrument
SCONfiguration:EXTernal:IQOutput:REMote:ISELect "SGS_1","A"
SCONfiguration:EXTernal:IQOutput:REMote:CONNect
SCONfiguration:EXTernal:IQOutput:INAMe?
// Response: "SGS_1 [A]"
// Use an user defined initialization file
// MMEMory:CDIRectory "/var/user/RcExtInstr"
// SCONfiguration:EXTernal:REMote:INITialization:CATalog?
// Response: init_seq_sgs
// SCONfiguration:EXTernal:IQOutput:REMote:INITialization:FILE "init_seq_sgs.iec"
SCONfiguration:EXTernal:ACONnect 1
*RST
SCONfiguration:EXTernal:REMote:PURGe
// Disabling remote control of the external instruments
SCONfiguration:EXTernal:REMote:DISConnect[:ALL]