Remote Control Commands
R&S
®
SMBV100B
668User Manual 1178.4460.02 ─ 03
Example:
SCONfiguration:EXTernal:IQOutput1:RCONnection:STATe?
// 1
SOURce:FREQuency:CW?
// 60000000000
SOURce1:IQ:OUTPup:ANALog:TYPE DIFFerential
SCONfiguration:EXTernal:PBEHaviour 1
*RST
SOURce:FREQuency:CW?
// 60000000000
SCONfiguration:EXTernal:IQOutput1:RCONnection:STATe?
// 1
SOURce1:IQ:OUTPup:ANALog:TYPE?
// DIFF
SCONfiguration:EXTernal:PBEHaviour 0
*RST
SOURce:FREQuency:CW?
// 1000000000
SCONfiguration:EXTernal:IQOutput1:RCONnection:STATe?
// 0
SOURce1:IQ:OUTPup:ANALog:TYPE?
// SING
Manual operation:
See "Preset behavior: Keep connections to external instru-
ments" on page 446
:SCONfiguration:EXTernal:DIGital:DIRection?
:SCONfiguration:EXTernal:IQOutput:DIRection?
Queries the connector direction.
Return values:
<Direction> NONE | IN | OUT
*RST: IN
Example: See Example "Connecting and configuring external instrument"
on page 662.
Usage: Query only
Manual operation: See "Direction" on page 446
:SCONfiguration:EXTernal:DIGital:IQConnection:STATe?
Queries the status of the I/Q connection of the digital interfaces.
Return values:
<IQConnState> 0 | 1 | OFF | ON
Example: See Example "Connecting and configuring external instrument"
on page 662.
SCONfiguration Subsystem

Table of Contents