Remote Control Commands
R&S
®
SMBV100B
673User Manual 1178.4460.02 ─ 03
Parameters:
<HwChan> String
Hardware channel (USB or LAN) used by the remote channel to
the external instrument
Range: "LAN" to "USB"
*RST: "LAN"
<TcpIporUsbAddr> String
IP address or hostname of the connected external instrument
<RfPathNumber> String
Determines the number of RF paths the external instrument is
equipped with
Range: "1" to "2"
*RST: "1"
Setting parameters:
<InstrName> String
Alias name of the instrument
Example: See Example "Connecting and configuring external instrument"
on page 662.
Usage: Setting only
Manual operation: See "External Instrument" on page 451
:SCONfiguration:EXTernal:REMote:REName
Changes the symbolic name of the instrument.
Example:
See Example "Connecting and configuring external instrument"
on page 662.
Usage: Setting only
:SCONfiguration:EXTernal:DIGital:REMote:DETect?
Searches for external instruments connected to the particular digital interfaces.
Return values:
<DetectedInstr> string
If the detection fails, the query returns "None".
Example: See Example "Connecting and configuring external instrument"
on page 662.
Usage: Query only
Manual operation: See "Detect/Scan" on page 450