:SCONfiguration:EXTernal:DIGital:REMote:ISELect <InstrName>[, <RfPath>]
:SCONfiguration:EXTernal:IQOutput:REMote:ISELect <InstrName>[, <RfPath>]
Select an external instrument for the selected connector.
Parameters:
<InstrName> String
Instrument alias name, as retrieved with the command :
SCONfiguration:EXTernal:REMote:LIST? or defined with
the command :SCONfiguration:EXTernal:REMote:ADD.
<RfPath> String
Determines the used RF output of the external instrument.
Example: See Example "Connecting and configuring external instrument"
on page 662.
Manual operation: See "External Instrument" on page 451
:SCONfiguration:EXTernal:DIGital:REMote:CONNect
:SCONfiguration:EXTernal:IQOutput:REMote:CONNect
Triggers the connection establishment.
Example:
See Example "Connecting and configuring external instrument"
on page 662.
Usage: Event
Manual operation: See "Apply and Connect" on page 452
:SCONfiguration:EXTernal:DIGital:REMote:INFO?
:SCONfiguration:EXTernal:IQOutput:REMote:INFO?
Queries information on the external instrument.
Return values:
<Info> string
Returns information in one of the following formats:
"None"
An external instrument is not assigned
<SymbolicName>,<RemoteChannel>,<RemoteAd-
dress>,<RF Path>
An external instrument is assigned, but not connected
<SymbolicName>,<RemoteChannel>,<RemoteAd-
dress>,<RF Path>[,<*IDN? String>]
An external instrument is assigned and connected
Example:
:SCONfiguration:EXTernal:DIGital:REMote:INFO?
"SGT (101676)","LAN","rssgt100a101676","A",
"Rohde&Schwarz,SGT100A,1419.4501k02/101676,3.1.19.4-3.18.251.99"
Usage: Query only