Remote Control Commands
R&S
®
SMBV100B
797User Manual 1178.4460.02 ─ 03
SOURce1:AWGN:DISP:MODE RFA
SOURce1:AWGN:POWer:MODE CN
SOURce1:AWGN:POWer:RMODe CARRier
SOURce1:AWGN:BRATe?
// Response: 100000
SOURce1:AWGN:CNRatio 12.7
SOURce1:AWGN:ENRatio?
// Response: 23.0342375548695
SOURce1:AWGN:POWer:CARRier?
// Response: -76
// the Level display indicates the PEP of the carrier
// Querry the resulting noise power, in the system and total bandwidht
SOURce1:AWGN:POWer:NOISe?
// Response: -88.7
SOURce1:AWGN:POWer:NOISe:TOTal?
// Response: -88.7
// Querry the carrier+noise power and PEP
SOURce1:AWGN:POWer:SUM?
// Response: -75.7728170942726
SOURce1:AWGN:POWer:SUM:PEP?
// Response: -76
[:SOURce<hw>]:AWGN:STATe........................................................................................797
[:SOURce<hw>]:AWGN:MODE....................................................................................... 798
[:SOURce<hw>]:AWGN:BWIDth......................................................................................798
[:SOURce<hw>]:AWGN:BWIDth:RATio............................................................................ 798
[:SOURce<hw>]:AWGN:BWIDth:NOISe?..........................................................................799
[:SOURce<hw>]:AWGN:DISP:MODE...............................................................................799
[:SOURce<hw>]:AWGN:POWer:MODE............................................................................799
[:SOURce<hw>]:AWGN:POWer:RMODe..........................................................................799
[:SOURce<hw>]:AWGN:BRATe....................................................................................... 800
[:SOURce<hw>]:AWGN:CNRatio.....................................................................................800
[:SOURce<hw>]:AWGN:ENRatio..................................................................................... 800
[:SOURce<hw>]:AWGN:POWer:CARRier.........................................................................800
[:SOURce<hw>]:AWGN:POWer:NOISe............................................................................801
[:SOURce<hw>]:AWGN:POWer:NOISe:TOTal?.................................................................801
[:SOURce<hw>]:AWGN:POWer:SUM?.............................................................................801
[:SOURce<hw>]:AWGN:POWer:SUM:PEP?..................................................................... 802
[:SOURce<hw>]:AWGN:FREQuency:TARGet................................................................... 802
[:SOURce<hw>]:AWGN:FREQuency:RESult?...................................................................802
[:SOURce<hw>]:AWGN:STATe <State>
Activates or deactivates the AWGN generator.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Generating a pure noise signal" on page 795.