EasyManua.ls Logo

Rohde & Schwarz SMBV100B - Page 806

Rohde & Schwarz SMBV100B
1030 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMBV100B
804User Manual 1178.4460.02 ─ 03
Parameters:
<Delay> float
Range: 0 to 10E-6
Increment: 1E-12
*RST: 0
Example:
SOURce:BB:IMPairment:RF1:DELay 32.0E-9
Manual operation: See "IQ Delay" on page 274
[:SOURce<hw>]:IQ:IMPairment:IQRatio[:MAGNitude] <Magnitude>
[:SOURce]:BB:IMPairment:IQOutput<ch>:IQRatio[:MAGNitude] <IqRatio>
[:SOURce]:BB:IMPairment:RF<ch>:IQRatio[:MAGNitude] <IqRatio>
Sets the ratio of I modulation to Q modulation (amplification imbalance) of the corre-
sponding digital channel.
Table 12-3: Value range
Impairments Min [dB] Max [dB] Resolution
Digital -4 4 0.0001
Analog -1 1 0.0001
Parameters:
<IqRatio> float
The setting value can be either in dB or %. An input in percent is
rounded to the closest valid value in dB.
Range: -4 to 4
Increment: 1E-4
*RST: 0
Default unit: dB | PCT (setting command) / dB (result value)
Example:
SOURce:BB:IMPairment:RF1:IQRatio:MAGNitude 10 PCT
SOURce:BB:IMPairment:RF1:IQRatio:MAGNitude?
// 0.848
// the value is returned in dB
Manual operation: See "Gain Imbalance" on page 273
[:SOURce<hw>]:IQ:IMPairment:LEAKage:I <I>
[:SOURce<hw>]:IQ:IMPairment:LEAKage:Q <Q>
[:SOURce]:BB:IMPairment:IQOutput<ch>:LEAKage:I <I>
[:SOURce]:BB:IMPairment:IQOutput<ch>:LEAKage:Q <Q>
[:SOURce]:BB:IMPairment:RF<ch>:LEAKage:I <I>
[:SOURce]:BB:IMPairment:RF<ch>:LEAKage:Q <Q>
Determines the leakage amplitude of the I or Q signal component of the corresponding
stream
SOURce Subsystem

Table of Contents