Remote Control Commands
R&S
®
SMBV100B
858User Manual 1178.4460.02 ─ 03
Rohde & Schwarz name SCPI name Command in manual control
AUTO IMMediate
MODE AUTO
SINGle BUS MODE SINGLE or STEP
EXTernal EXTernal MODE EXT TRIG SINGLE or
EXT TRIG STEP
Parameters:
<Source> SINGle | BUS | AUTO | EXTernal | IMMediate
AUTO|IMMediate
The trigger is free-running, i.e. the trigger condition is fulfilled
continuously. The selected list is restarted as soon as it is fin-
ished.
SINGle|BUS
The list is triggered by the command [:SOURce<hw>]:LIST:
TRIGger:EXECute. The list is executed once.
EXTernal
The list is triggered externally and executed once.
*RST: AUTO
Example: See Example "Create an RF list and activate the list mode"
on page 850.
Manual operation: See "Mode" on page 337
[:SOURce<hw>]:LIST:RUNNing?
Queries the current state of the list mode.
Return values:
<State> 0 | 1 | OFF | ON
1
Signal generation based on the list mode is active.
Example: See Example "Create an RF list and activate the list mode"
on page 850.
Usage: Query only
12.16.11.2 List Mode File Operation
The following section covers basic commands to file handling in list mode.
[:SOURce<hw>]:LIST:CATalog?.......................................................................................859
[:SOURce<hw>]:LIST:DELete..........................................................................................859
[:SOURce<hw>]:LIST:DELete:ALL................................................................................... 859
[:SOURce<hw>]:LIST:FREE?.......................................................................................... 860
[:SOURce<hw>]:LIST:RESet........................................................................................... 860
[:SOURce<hw>]:LIST:SELect.......................................................................................... 860
SOURce Subsystem