Remote Control Commands
R&S
®
SMC100A
268Operating Manual 1411.4060.32 ─ 09
7.12 SENSe, READ and INITiate Subsystems
The SENSe subsystem contains the commands for configuring the power measure-
ments with R&S NRP-Zxx power sensor(s) connected to the generator. The measure-
ment is started and the measurement result retrieved with the READ command. The
description of this commands is included in the following.
Up to four sensors can be connected to the signal generator. They are distinguished by
means of the suffix under SENSe, that means SENSe [1] ... SENSe 4.
:SENSe<ch>[:POWer]:APERture:DEFault:STATe............................................................. 268
:SENSe<ch>[:POWer]:APERture:TIMe.............................................................................269
:INITiate<ch>[:POWer]:CONTinuous................................................................................269
:READ<ch>[:POWer]?.................................................................................................... 269
:SENSe<ch>[:POWer]:CORRection:SPDevice:STATe....................................................... 270
:SENSe<ch>[:POWer]:DISPlay:PERManent:STATe.......................................................... 270
:SENSe<ch>[:POWer]:DISPlay:PERManent:PRIority.........................................................271
:SENSe<ch>[:POWer]:FILTer:LENGth:AUTO?..................................................................271
:SENSe<ch>[:POWer]:FILTer:LENGth[:USER]..................................................................271
:SENSe<ch>[:POWer]:FILTer:NSRatio.............................................................................272
:SENSe<ch>[:POWer]:FILTer:NSRatio:MTIMe..................................................................272
:SENSe<ch>[:POWer]:FILTer:SONCe..............................................................................273
:SENSe<ch>[:POWer]:FILTer:TYPE................................................................................ 273
:SENSe<ch>[:POWer]:LOGGing:STATe...........................................................................274
:SENSe<ch>[:POWer]:FREQuency..................................................................................274
:SENSe<ch>[:POWer]:OFFSet........................................................................................274
:SENSe<ch>[:POWer]:OFFSet:STATe............................................................................. 274
SENSe<ch>[:POWer]:SNUMber?.................................................................................... 275
:SENSe<ch>[:POWer]:SOURce.......................................................................................275
SENSe<ch>[:POWer]:STATus[:DEVice]?......................................................................... 275
SENSe<ch>[:POWer]:SVERsion?....................................................................................276
SENSe<ch>[:POWer]:TYPE?..........................................................................................276
:SENSe<ch>[:POWer]:ZERO.......................................................................................... 276
:SENSe<ch>:UNIT[:POWer]............................................................................................277
:SENSe<ch>[:POWer]:APERture:DEFault:STATe <UseDefAp>
Deactivates the default aperture time of the respective sensor.
To specify a user-defined value, use the command :SENSe<ch>[:POWer]:
APERture:TIMe on page 269.
Parameters:
<UseDefAp> 0 | 1 | OFF | ON
*RST: 1
Example:
SENS:POW:APER:DEF:STAT 0
deactivates the default aperture time of the sensor.
Manual operation: See "Use Default Aperture Time" on page 154