SME Memory Sequence
1038.6002.02 2.149 E-13
SINGLE
Single run from the beginning to the end of the list. If SINGLE is selected, the
run is not yet started. Below the MODE line, function EXECUTE SINGLE
SEQUENCE
➤
to be executed is displayed which can be used to start the run.
IEC-bus short command :SYST:MODE MSEQ;
:SYST:MSEQ:MODE AUTO
:TRIG:MSEQ:SOUR SING
STEP
Step-by-step manual processing of the list. Activating STEP stops an automatic
run and the cursor wraps to the indication value of CURRENT INDEX. The list
can now be passed through upwards or downwards step by step using the
rotary knob.
IEC-bus short command :SYST:MODE MSEQ;
:SYST:MSEQ:MODE STEP
:TRIG:MSEQ:SOUR SING
EXT-SINGLE
Single run from the beginning to the end of the list as with SINGLE, but
triggered by an external trigger signal.
IEC-bus short command :SYST:MODE MSEQ;
:SYST:MSEQ:MODE AUTO
:TRIG:MSEQ:SOUR EXT
EXT-STEP
Step-by-step run using the external trigger signal. Each trigger event triggers a
single step.
IEC-bus short command :SYST:MODE MSEQ;
:SYST:MSEQ:MODE STEP
:TRIG:MSEQ:SOUR EXT
OFF
Step-by-step run using the external trigger signal. Each trigger event triggers a
single step.
IEC-bus short command :SYST:MODE FIX