SME Memory Sequence
1038.6002.02 2.151 E-13
The second page of menu MEM SEQ, the EDIT page, is automatically activated if one of the editor
functions of the FUNCTION line is selected. The list which is entered as CURRENT LIST in the
SELECT LIST line is shown.
FREQUENCY
LEVEL
MODULATION
DIGITAL MOD
LF OUTPUT
SWEEP
LIST
MEM SEQ
UTILITIES
HELP
CURRENT: MSEQ1
DELETE
FREQ
100. 000 000 0
MHz
LEVEL
-30.0
dBm
INSERTFILL
EDIT/VIEW
SELECT LIST...
FUNCTION
-INDEX - FREE 2041 - LEN 2055 MEMORY DWELL
001
09 50 ms
002 02 50 ms
003 01 60 ms
004 23 60 ms
005 09 85 ms
006 10 85 ms
007 08 85 ms
008 11 85 ms
Fig. 2-62 Menu MEM SEQ - EDIT page
INDEX
Index of the list.
FREE
Indication of the list entries still vacant.
LEN
Length of the current list.
MEMORY
Parameter: number of memory location; range 1 to 50.
DWELL
Parameter: dwell time; specified range 50 ms to 60 sec, step width 1 ms.