EasyManua.ls Logo

Rohde & Schwarz SME02 - Output2 System

Rohde & Schwarz SME02
462 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OUTPut2 SME
1038.6002.02 3.28 E-13
3.6.10 OUTPut2 System
This system contains the commands specifying the characteristics of the LF output socket
Command Parameter Default
Unit
Remark
:OUTPut2
:SOURce
:STEReo
[:STATe]
:VOLTage
0 | 2
MPX | PILot
ON | OFF
0 V to 4 V V
Option SM-B2
Option SM-B6
Option SM-B6
:OUTPut2:SOURce 0 | 2
This command selects which LF generator is connected with the LF output socket (only with
option SM-B2 and SM-B6).
0 LF generator 1
2 LF generator 2 *RST value is 0, LF-generator 1 is connected at the output.
Example: :OUTP2:SOUR 2
:OUTPut2:SOURce:STEReo MPX | PILot
The command determines whether the complete stereo multiplex signal (MPX) or only the pilot
tone is output. The command is only effective if LF generator2 is in the STEREO operating mode
and if LF generator2 is selected for OUTPut2:SOURce as well.
Example: :OUTP2:SOUR:STER MPX *RST value is MPX
:OUTPut2[:STATe] ON | OFF
The command switches the LF output on or off. *RST value is OFF
Example: :OUTP2:STAT ON
:OUTPut2:VOLTage 0V to 4V
The command sets the voltage of the LF output. The voltage is a characteristic of the output, not
the source. I.e., it is maintained even if another LF generator is connected to the output.
Example: :OUTP2:VOLT 3.0V *RST value is 1 V