SME SOURce:ERMes
1038.6002.02 3.53 E-133
[:SOURce]:ERMes:MESSage:TONE 0 to 15
The command specifies which of the 16 tones possible (8 normal, 8 urgent) are transmitted in an
tone-only message. This command is only effective if CATegory TONE has been selected.
Example: :SOUR:ERM:MESS:TONE 7 *RST value is 0
[:SOURce]:ERMes:NINFormation
The commands to set the data denoting the network (the SME simulates) in greater detail are
under this node. These data are part of every message sent (cf. ERMES standard).
[:SOURce]:ERMes:NINFormation:OPERator 0 to 7
The command sets the code of the network operator. *RST value is 0
Example: :SOUR:ERM:NINF:OPER 1
[:SOURce]:ERMes:NINFormation:PA | PARea 0 to 63
The command sets the paging area. *RST value is 0
Example: :SOUR:ERM:NINF:PA 4
[:SOURce]:ERMes:NINFormation:ZCOuntry 0 to 799
The command sets the zone and the country code in the message to be sent. Germany has code
262 *RST value is 262
Example: :SOUR:ERM:NINF:ZCO 799
[:SOURce]:ERMes:SEQuence
The commands specifying the structure of the message subsequences are under this node. The
control of the subsequence (message or fill subsequences, cf. Chapter 2, Section
"Radiocommunication Service ERMES") is effected via the TRIGger system.
[:SOURce]:ERMes:SEQuence:DBATch A to P {,A toP}
The command indicates the batches which are to contain message data.
After *RST value, no batch contains user data
Example: :SOUR:ERM:SEQ:DBAT A, B, C, G, H, M, P
[:SOURce]:ERMes:SI|SINFormation
The commands to set the sending system are under this node (cf. ERMES standard). The data
are part of every message sent.
[:SOURce]:ERMes:SI|SINFormation:BAI ON | OFF
The command sets the Border Area Indicator Bit. *RST value is OFF
Example: :SOUR:ERM:SI:BAI ON