SOURce:ERMes SME
1038.6002.02 3.54 E-13
[:SOURce]:ERMes:SI|SINFormation:ETI ON | OFF
The command sets the External Traffic Indicator Bit. *RST value is OFF
Example: :SOUR:ERM:SI:ETI ON
[:SOURce]:ERMes:SI|SINFormation:FSI 0 to 30
The command sets the Frequency Subset Indicator. According to the standard, one-channel
networks have an FSI of 30. *RST value is 30
Example: :SOUR:ERM:SI:FSI 20
[:SOURce]:ERMes:SI|SINFormation:DOMonth 1 to 31
The command sets the date (day of month). *RST value is 1
Example: :SOUR:ERM:SI:DOM 24
[:SOURce]:ERMes:SI|SINFormation:TIME 00,00 to 23,59
The command sets the time. *RST value is 00,00
Example: :SOUR:ERM:SI:TIME 12,00
[:SOURce]:ERMes:TACTion MESSage | STARt | ONCE
This command (Trigger ACT
ion) determines the action which is activated by a trigger event. The
valid trigger events are specified by command TRIGger:DM:SOURce. This command also
defines the allocation between manual and remote-control operations.
MESSage A trigger event switches from filler data output to useful data output for the duration
of a subsequence (12 s). The filler data are then output again.
STARt Digital modulation is started by a trigger event. Useful data are then continuously
output according to the settings.
This setting is suitable, for example, for a synchronous start of several units.
ONCE The output of the message subsequence is only started by a valid trigger event.
After recognition of this signal, exactly one message subsequence (length: 12
seconds) is output. After that, the SME waits for its trigger pulse again (defined
under TRIG:DM:SOUR).
Example: :SOUR:ERM:TACT MESS *RST value is MESSage