SOURce:ILS SME
1038.6002.02 3.68 E-13
3.6.11.8 SOURce:ILS Subsystem
This subsystem contains the commands to control the characteristics of the test signals for ILS
(Instrument L
anding System) (option SM-B6, multifunction generator).
Command Parameter Default
Unit
Remark
[:SOURce]
:ILS
:STATe
:SOURce
:TYPE
[:GS | GSLope]
:MODE
:COMid
[:STATe]
:FREQuency
:DEPTh
:DDM
:CURRent
[:DEPTh]
:DIRection
:LOGarithmic
:LLOBe
[:FREQuency]
:ULOBe
[:FREQuency]
:PHASe
:PRESet
:SODepth
:LOCalizer
:MODE
:COMid
[:STATe]
:FREQuency
:DEPTh
:DDM
:CURRent
[:DEPTh]
:DIRection
:LOGarithmic
:LLOBe
[:FREQuency]
:RLOBe
[:FREQuency]
:PHASe
:PRESet
:SODepth
ON | OFF
INT2 | INT2, EXT
GS | GSLope | LOCalizer
NORM | ULOBe | LLOBe
ON | OFF
0.1 to 20 000 Hz
0 to 100 PCT
-685 uA to+685uA
-0.8 to +0.8
UP | DOWN
-999.9 to +999.9
100 to 200 Hz
60 to 120 Hz
0 to 120 deg
0 to 100 PCT
NORM | LLOBe | RLOBe
ON | OFF
0.1 to 20 000 Hz
0 to 100 PCT
-387 to +387 uA
-0.4 to +0.4
LEFT | RIGHt
-999.9 to +999.9
60 to 120 Hz
100 to 200 Hz
0 to 120 deg
0 to 100 PCT
Hz
PCT
A
Hz
Hz
rad
PCT
Hz
PCT
A
Hz
Hz
rad
PCT
Option SM-B6
No query
No query

Table of Contents