SOURce:MBEacon SME
1038.6002.02 3.80 E-13
3.6.11.11 SOURce:MBEacon Subsystem
This subsystem contains the commands to control the characteristics of the marker signals (Marker
BEacon) as they are used to mark the distance in the approach range of airports (option SM-B6,
multifunction generator).
Command Parameter Default
Unit
Remark
[:SOURce]
:MBEacon
:STATe
[:MARKer]
:FREQuency
:DEPTh
:COMid
[:STATe]
:FREQuency
:DEPTh
ON | OFF
400 Hz | 1300 Hz | 3000 Hz
0 to 100 PCT
ON | OFF
0.1 to 20 000 Hz
0 to 100 PCT
Hz
PCT
Hz
PCT
Option SM-B6
[:SOURce]:MBEacon:STATe ON | OFF
The command switches on or off the generation of marker beacon signals. STATe ON is only
possible if no amplitude modulation is switched on. Modulation generator 2 must not be inserted
simultaneously as a source for PM or FM either.
Example: :SOUR:MBE:STAT ON *RST value is OFF
[:SOURce]:MBEacon[:MARKer]:FREQuency 400 Hz | 1300 Hz | 3000 Hz
The command selects the frequency of the marker signal. *RST value is 400 Hz
Example: :SOUR:MBE:MARK:FREQ 400
[:SOURce]:MBEacon[:MARKer]:DEPTh 0 to 100 PCT
The command selects the frequency of the marker signal. *RST value is 95 PCT
Example: :SOUR:MBE:MARK:DEPT 95PCT
[:SOURce]:MBEacon:COMid[:STATe] ON | OFF
The command activates or deactivates the ComId signal. *RST value is OFF
Example: :SOUR:MBE:COM:STAT ON
[:SOURce]:MBEacon:COMid:FREQuency 0.1 to 20 000 Hz
The command sets the frequency of the ComId signal. *RST value is 1020 Hz
Example: :SOUR:MBE:COM:FREQ 1020
[:SOURce]:MBEacon:COMid:DEPTh 0 to 100 PCT
The command sets the AM modulation depth of the ComId signal *RST value is 5 PCT
Example: :SOUR:MBE:COM:DEPT 5PCT