SOURce:REFLex25 SME
1038.6002.02 3.98 E-13
[:SOURce]:REFLex25:FCONtent “I|A|N|T|S|R|B|F|O|1|2|3|4|5|6|7|8|9
[,I|A|N|T|S|R|B|F|O|1|2|3|4|5|6|7|8|9]“
This command specifies the contents of the max. 128 frames the SME sends during a cycle. A
string with a length of max. 128 characters can be transferred. Each of the 128 frames is
represented by a character which may assume one of the following values:
Character Status display Frame contents
I
IDLE ReFLEX25 frame without addresses and message contents
A
ALPH ReFLEX25 frame with alphanumeric message and address
N
NUM ReFLEX25 frame with numeric message and address
T
TONE ReFLEX25 frame with tone-only message and address
S
SCI SCI frame
R
RSYN Emergency Resynchronization Frame
B
BER ReFLEX25 frame with a message that switches the receiver to the bit-error-test mode
F
FPAT ReFLEX25 test filler pattern according to section 10.1 of the ReFLEX25 standard
O
OTH Simulated data of another radiocommunication service; contains no ReFLEX
structures at all.
1 to 9
CUS1 to CUS9 Custom frames, freely definable by the user (see instructions in the manual operation
part)
Notes: – A cycle can be reduced to less than 128 frames by transferring a string with less than
128 characters. In this case, the SME starts the next cycle earlier.
– :REFL25:FCONtent can also be changed with ReFLEX25 being active.
– For using the frame types BER and FPAT, see also section „Bit Error Rate Test“ in the
manual operation part.
Example: SOUR:REFL25:FCON “SAAAA....“ RST value is “SAAAA... “(abbreviated)
[:SOURce]:REFLex25:AADaptation ON | OFF
If :REFL25:AADaptation is set to ON, the following settings are performed automatically as
soon as ReFLEX25 is switched on:
:REFL25:SI:FCH:BASE, :REFL25:SI:FCH:ANUMber and :REFL25:SI:FSPacing are used
to calculate and set the RF.
The values set automatically can be changed subsequently without recalculation of the telegram.
These modifications take effect immediately. However,. they do not react on the output
parameters (:REFL25:SI:FCH:SCIBase etc., see above).
Example: SOUR:REFL25:AAD ON *RST value is ON
[:SOURce]:REFLex25:TACTion MESSage | STARt | ONCE
This command (Trigger ACTion) determines the action triggered by a trigger event. The valid
trigger events (free-running, external signal, *TRG etc.) are specified by the command
TRIGger:DM:SOURce. The assignment manual operation/remote control is also described with
this command.
MESSage A valid trigger event causes the next ALPH, NUM or TONE frame (see
:REFL25:FCONtent) to be actually output as such and not as IDLE frame.
STARt The output of the ReFLEX telegram is only started by a valid trigger event. Then the
frames are sent exactly as specified in :REFL25:FCONtent until :REFL25:STATe
is switched to OFF. This setting is suitable for starting several SMEs synchronously.
ONCE The output of the ReFLEX telegram is only started by a valid trigger event. After
recognition of this signal, exactly one cycle (up to 128 frames) is output. The frames
are output exactly as specified in REFL25:FCONT. After execution of the cycle, the
SME waits for its trigger pulse again (defined under TRIG:DM:SOUR).
Example: SOUR:REFL25:TACT MESS *RST value is MESS