Digital Standard IS-95 CDMA SMIQ
1125.5555.03 E-92.144
SAVE/RCL
MAPPING...
Saves/calls up the set channel configuration.
This setting is only possible in the forward link mode.
For FWD_LINK_18, the following is saved for each channel number:
- selected WALSH CODE
- set POWER
- type of modulation data (DATA) and
- switch-on state.
For FWD_LINK_64, the following is saved for each channel number:
- set POWER
- modulation data (DATA) and
- switch-on state.
The channel configuration of the two forward-link modes is stored and loaded
at the same time.
FREQ
100. 000 000 0
MHz
FREQUENCY
LEVEL
ANALOG MOD
VECTOR MOD
DIGITAL MOD
DIGITAL STD
LF OUTPUT
SWEEP
LIST
MEM SEQ
UTILITIES
IS95
PHS
IS-95
MODE
SET DEFAULT
MODULATION...
TRIGGER MODE
EXECUTE TRIGGER>
TRIGGER....
CLOCK...
TOTAL POWER
ADJUST TOTAL
SAVE/RCL MAP
GET PREDEFINED MAPPING...
RECALL MAPPING...
SAVE MAPPING...
DELETE MAPPING...
LEVEL
-30.0
dBm
PEP
-13.9.
dBm
Fig. 2-85 Menu DIGITAL STD - IS-95 - SAVE/RCL MAPPING..., equipped with options
modulation coder SMIQB20, data generator SMIQB11 and SMIQB42
(SAVE/RCL
MAPPING...)
GET PREDEFINED
MAPPING...
Loads a factory-set channel configuration.
PILOT A pilot signal is generated only.
09CHAN A signal with 9-code channels is
generated according to the Base Station
Test Model (IS95).
18CHAN A signal with 18-code channels is
generated.
IEEE-bus :SOUR:IS95:MAPP:SEL:PRED "pilot"
RECALL MAPPING...
Loads a stored channel configuration.
IEEE-bus :SOUR:IS95:MAPP:LOAD "name"