SMIQ Enhanced Functions For Digital Standard 3GPP W-CDMA (FDD)
1125.5555.03 E-92.249
TIMING OFFSET
Sets a time offset (0 to 149) with which the corresponding downlink enhanced
channels are sent. (The resulting crest factor of the overall signal can be
influenced).
The timing offset can be set in an interval of 256 chips.
IEC/IEEE-bus command :SOUR:W3GP:BST:ENH:TOFF 1
PILOT LENGTH
Sets the pilot field size in the timeslots of the corresponding downlink
enhanced channels (2, 4, 8 or 16 depending on the symbol rate).
IEC/IEEE-bus command :SOUR:W3GP:BST:ENH:PLEN BIT4