EXECUTE
TRIGGER
Executes a trigger even to start the DECT signal generation. This menu item
is not available if TRIGGER MODE - AUTO is set.
IEC/IEEE-bus command
:TRIG:DM:IMM
TRIGGER...
Opens a window for selecting the trigger source, for configuring the trigger
output signals and for setting the time delay of an external trigger signal.
FREQ
100. 000 000 0
MHz
FREQUENCY
LEVEL
ANALOG MOD
VECTOR MOD
DIGITAL MOD
DIGITAL STD
LF OUTPUT
SWEEP
LIST
MEM SEQ
UTILITIES
DECT
PHS
IS-95
NADC
PDC
GSM
DECT
STATE
MODULATION...
TRIGGER MODE
EXECUTE TRIG
TRIGGER....
CLOCK...
POWER RAMP C>
SLOT ATTENUA
TRIGGER SOURCE
INT EXT
EXT TRIGGER DELAY 0 Symb
EXT RETRIGGER INHIBIT 0 Symb
TRIGGER OUT2 DELAY 0 Symb
TRIGGER OUT2 PERIOD 1 Frame
LEVEL
-30.0
dBm
PEP
- 30.0
dBm
FULL
01
Fig. 2-207 Menu DIGITAL STD - DECT_TRIGGER..., SMIQ equipped with Modulation Coder
SMIQB20 and Data Generator SMIQB11
(TRIGGER...) TRIGGER SOURCE
Selection of trigger source.
EXT The DECT signal generation is started
by the active slope of an external trigger
signal.
The polarity, the trigger threshold and
the input resistance of the TRIGIN input
can be modified in menu DIGITAL MOD
- EXT INPUTS.
INT A trigger event can be executed by
EXECUTE TRIGGER
.
IEC/IEEE-bus
:SOUR:DECT:TRIG:SOUR EXT